Parapet coping fixing details

How a Taylormade coping goes on a parapet wall. Two standard details, adhesive bonded and concealed mechanical fixing, each shown on three wall types. The details show how our coping fits. Fire stopping, cavity closers and the rest of the wall build-up are for the architect to confirm.

Curved lightweight parapet coping fitted on a brick wall below a tiled roof

Parapet coping, adhesive bonded

The coping has a 40mm recess in its underside, so it sits down over the wall head. It is bedded on three strips: two adhesive strips with a strip of Insta-Stik foam between them for quick secondary fixing. Below the bed go a liquid membrane, a 9mm cement board and a DPC. Choose a wall type to see its section.

440mm
Coping width in this detail
40mm
Recess over the wall head
3 strips
Two adhesive, one Insta-Stik
4mm
Polymer basecoat on every exposed face
Section A-A, TMF-SD-001A, wall type 2: Brick, 100mm cavity, 100mm block

Scroll sideways, or tap the drawing to open it full size.

Section A-A, TMF-SD-001A Rev J, wall type 2. Dimensions in mm. Do not scale.
Wall types in the TMF-SD-001A standard
Wall typeWall widthOverhang each side
1 Brick, 50mm cavity, timber frame314mm63mm
2 Brick, 100mm cavity, 100mm block302.5mm68.8mm
3 Rendered 100mm block, 100mm cavity, 100mm block300mm plus render70mm

Parapet coping, mechanical fixing

Mechanical fixing is rarely needed and is reviewed at design stage, but it can be supplied on any coping if the architect asks for it. Where it is used, a galvanised steel dovetail rail is fixed into the underside of each coping and screwed through to the wall at each joint. The rail sits fully embedded in the coping and cannot be seen from outside. The 3-strip adhesive bed stays in place.

50 × 10.5mm
Galvanised steel dovetail rail
700mm
Rail length, centred on each coping joint
6 × 120
Screw at each rail, into an 8 × 65 plug
Hot-wire cut
Slot cut in the factory, rail fully embedded
Section A-A, TMF-SD-001B, wall type 2: Brick, 100mm cavity, 100mm block

Scroll sideways, or tap the drawing to open it full size.

Section A-A, TMF-SD-001B Rev A, wall type 2. Dimensions in mm. Do not scale.
Wall types in the TMF-SD-001B standard
Wall typeWall widthOverhang each side
1 Brick, 50mm cavity, timber frame314mm63mm
2 Brick, 100mm cavity, 100mm block302.5mm68.8mm
3 Rendered 100mm block, 100mm cavity, 100mm block300mm plus render70mm
Download the drawings (PDF, 58 KB)

Fitting at each joint

01

Bed the first coping

The rails slide half into their slots and the coping is bedded on the 3-strip bed.

02

Fix at the joint

Screw through the rail into the plug in the wall. On timber frame, screw straight into the head plate.

03

Slide the next coping on

The next coping closes onto the other half of each rail.

What is supplied

Liquid membrane, cement board and fixings are supplied by Taylormade Facades where required, or by others as agreed.

Joint widths and jointing materials vary from project to project and are set by the architect. The model and sections show design intent only. Fixing centres, adhesive coverage and the interface with the rest of the wall are confirmed on the approved project drawing.

Send us your parapet details and we will confirm the coping and the fixing for your wall. Drawings back in 5–10 working days, depending on project complexity. See also how all our profiles are fixed and our parapet cappings.

Get a Quote for Your Project

Send us your drawings and we will come back with a coordinated profile proposal.

Request a Quote